Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 111
Filter
1.
Rev. bras. cir. cardiovasc ; 39(1): e20230186, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1521678

ABSTRACT

ABSTRACT In this article, we present the case of a 47-year-old man who underwent Bentall-Bono procedure and frozen elephant trunk prosthesis implantation due to severe aortic regurgitation and aortic dilatation with a second-time endovascular stent-graft repair in descending aorta. Over eight years, a subacute graft infection by Propionibacterium acnes was developed, culminating in cardiogenic shock secondary to severe aortic regurgitation due to a complete aortic root dehiscence because of multiple aortic pseudoaneurysms. The patient underwent emergency surgery in which the replacement of the graft by a biological valve tube was performed accompanied by a complete debranching of the three supra-aortic vessels.

2.
Rev. argent. cardiol ; 91(2): 125-137, jun. 2023. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1529590

ABSTRACT

RESUMEN Introducción : El reemplazo de la raíz aórtica con conservación valvular (valve-sparing aortic root replacement, VSAR) se ha consolidado como un procedimiento eficaz para el tratamiento del aneurisma de la raíz aórtica, el síndrome de Marfan, la válvula bicúspide y la disección aórtica. Sin embargo, es necesario llegar a una opinión unánime sobre los aspectos clave del VSAR. Material y métodos : Se realizó una revisión bibliográfica de los debates y controversias más frecuentes del VSAR. A partir de esta información se elaboró una encuesta en línea que se envió a cirujanos con experiencia comprobada en VSAR para conocer su opinión sobre los factores relacionados con los pacientes, los aspectos técnicos, la ecocardiografía, la investigación, la formación y el futuro del VSAR. Resultados : Veinte cirujanos completaron la encuesta. Según 14 de cada 20 encuestados, la fracción de eyección grave se consideró una contraindicación para el llevar a cabo este procedimiento. El límite del diámetro del anillo aórtico para la remodelación fue heterogéneo entre los participantes. Todos ellos consideraron que el VSAR es un procedimiento seguro para los pacientes con síndrome de Marfan y válvula bicúspide. En el caso de disección de tipo A, 11 de cada 20 prefirieron este procedimiento solo para los pacientes jóvenes. En lo que respecta al tamaño del injerto, la altura del triángulo intervalvar (8/20) y el diámetro sinotubular (7/20) fueron los más frecuentes. Los cirujanos informaron una tasa de fracaso del 7% en la conversión al procedimiento de Bentall, y un cambio de estrategia intraoperatoria del 26%. No se consideró que un abordaje mínimamente invasivo mejorara los resultados. La mayoría de los cirujanos coincidieron en que el VSAR lo deben realizar cirujanos con mucha experiencia. Conclusiones : El VSAR ha sido aceptado como una opción terapéutica para el aneurisma de la raíz aórtica, y, aunque todavía no es posible llegar a un consenso definitivo, se presenta la valiosa experiencia de los cirujanos más destacados en este campo.


ABSTRACT Background : The valve-sparing aortic root replacement (VSAR) has been established as a successful procedure for aortic root aneurysms, Marfan's syndrome, bicuspid valves, and aortic dissections. However, there is a need for a consensus opinion regarding key aspects of VSAR. Methods : A literature review was performed regarding the most frequent debates and controversies in VSAR. An online survey was developed based on this information, and sent to surgeons with known expertise in VSAR regarding their opinion on patient-related factors, technical aspects, echocardiography, research, training, and the future of VSAR. Results : Twenty surgeons completed the survey. The reduction of left ventricular ejection fraction was considered a contra indication to VSAR when severe by 14/20 surveyed. The aortic annulus diameter cutoff point for the remodeling was heterogenous among participants. All of them felt that VSAR is safe for the Marfan´s syndrome population and bicuspid valves. For type A dissections, 11/20 preferred this procedure only in young patients. Regarding to graft sizing, the height of the interleaflet triangle (8/20) and the sino-tubular diameter (7/20) were the more frequent considered parameters. Surgeons reported a 7% of failure rate, leading to conversion to Bentall surgery, and a 26% change of strategy intraoperatively. A minimally invasive approach was not considered to improve results. Most of the surgeons agreed that VSAR should be performed by high-experienced surgeons. Conclusions : The VSAR has been accepted as a treatment option for the aortic root´s aneurysms, and even though there is still not possible to reach a final consensus, a valuable experience from the most relevant surgeons in the field is presented.

3.
Rev. argent. cardiol ; 91(1): 20-26, abr. 2023. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1529566

ABSTRACT

RESUMEN Objetivo : Analizar si la estrategia del implante alto usando superposición de las cúspides derechas e izquierdas (Cusp Overlap, COVL) en el implante percutáneo de la válvula aórtica (TAVI) se relaciona con menor incidencia de regurgitación paravalvular (RPV) moderada o grave, comparada con la estrategia convencional (CON). Material y métodos : Se analizaron 206 pacientes consecutivos que recibieron TAVI con válvulas autoexpandidles entre agosto de 2019 y mayo de 2022. Se utilizó una estrategia CON en 101 pacientes (49%) y COVL en 105 (51%). El Punto Final Primario (PFP) fue la presencia de regurgitación paravalvular moderada y grave a 30 días. Resultados : No hubo diferencia clínica entre los grupos en cuanto a la edad media, sexo ni comorbilidades; excepto una tendencia a más diabetes y angioplastia coronaria previa en el grupo COVL. El STS score fue mayor en el grupo de COVL (6,9 ± 2,2 vs. 5,8 ± 2,4 en CON, p = 0,01). A 30 días no hubo diferencia en el PFP (RPV moderada en 2% en CON, y 0,9% en COVL; ninguno presentó RPV grave). Tampoco hubo diferencia en mortalidad, infarto, oclusión coronaria, accidente cerebrovascular, sangrado mayor y complicación vascular. La necesidad de marcapasos definitivo fue menor con la estrategia de COVL (6,7% vs. 17,8%, p = 0,01) y un nuevo bloqueo de rama izquierda ocurrió en 5,7% vs. 12,9% (p = 0,07). Conclusiones : En esta serie de un solo centro, la estrategia del implante alto de la válvula aórtica percutánea usando la técnica de COVL no demostró diferencia en la presencia de regurgitaciones moderadas o graves comparada con la estrategia convencional, sin presentar diferencia en las complicaciones, y se asoció a una menor necesidad de marcapasos definitivo y a una tendencia de menos bloqueos de rama izquierda a 30 días.


ABSTRACT Objective : The aim of this study is to whether higher transcatheter aortic valve implantation (TAVI) with self-expandable valves using the right and left cusp overlap strategy (Cusp Overlap, COVL) is associated with a lower incidence of moderate or severe paravalvular regurgitation, compared with the conventional strategy (CON). Methods : A total of 206 consecutive patients undergoing TAVI with self-expandable valves between August 2019 and May 2022 were analyzed. The CON technique was used in the first 101 patients (49%) and COVL was used in 105 (51%). The primary endpoint (PEP) was the presence of moderate or severe paravalvular regurgitation at 30 days. Results : There were no clinical differences between the groups in terms of mean age, sex or comorbidities, except for a trend towards more patients with diabetes and previous percutaneous coronary intervention in the COVL group. The STS score was greater in the COVL group (6.9 ± 2.2 vs. 5.8 ± 2.4 in the CON group; p = 0.01). There was no difference in the PEP at 30 days with 2% incidence of moderate PVR in the CON group and 0.9% in the COVL group, and none of them presented severe PVR. There were no differences in mortality, myocardial infarction, coronary artery obstruction, stroke, major bleeding or vascular complications. The need for permanent pacemaker was lower with the COVL strategy (6.7% vs. 17.8%, p = 0.01) and a new left bundle branch block occurred in 5.7% vs. 12.9% (p = 0.07). Conclusions : In this single-center series, the strategy of high transcatheter aortic valve implantation using the COVL strategy showed no difference in the presence of moderate or severe regurgitation compared with the conventional strategy, with no differences in complications, and was associated with a lower need for definitive pacemaker and with a trend towards lower incidence of left bundle branch block at 30 days.

4.
Autops. Case Rep ; 13: e2023449, 2023. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520268

ABSTRACT

ABSTRACT Giant cell arteritis (GCA) is a type of chronic vasculitis that affects medium and large-caliber arteries, frequently related to aortic involvement and, consequently, to aneurysm formation. However, associated valvulitis with giant cells is uncommon. We describe the case of a 50-year-old female patient with aortic aneurysm and valvular insufficiency, whose anatomopathological examination revealed giant-cell aortic valvulitis associated with giant cell aortitis.

5.
Article in Spanish | LILACS, UY-BNMED, BNUY | ID: biblio-1520020

ABSTRACT

La sífilis es causada por Treponema pallidum, es reconocida por la variedad de sus manifestaciones clínicas; compromete el sistema nervioso, tegumentario y cardiovascular. Las alteraciones cardiovasculares ocurren en 70% de los casos con sífilis no tratada, el 71% de las aortitis sifilíticas desarrollan aneurismas aórticos y la complicación más frecuente es la insuficiencia aórtica. El tratamiento va dirigido a la enfermedad subyacente, con manejo antibiótico para la sífilis terciaria y las complicaciones tromboembólicas y si requiere reparación quirúrgica. Presentamos un caso poco frecuente de un paciente diagnosticado de infección por el virus de la inmunodeficiencia humana y complicaciones cardiovasculares típicas de la sífilis terciaria, que precisó tratamiento médico y quirúrgico, que fue exitoso. Destacamos la pericia clínica de los profesionales de nuestra institución para diagnosticar e identificar las complicaciones cardiovasculares de la sífilis terciaria.


Syphilis is caused by Treponema pallidum and is recognized by the variety of its clinical manifestations; it involves the nervous, integumentary and cardiovascular systems. Cardiovascular alterations occur in 70% of cases with untreated syphilis, 71% of syphilitic aortitis develop aortic aneurysms and the most frequent complication is aortic insufficiency. Treatment is directed at the underlying disease, with antibiotic treatment for tertiary syphilis and thromboembolic complications and if necessary surgical repair. We present a rare case of a patient diagnosed with human immunodeficiency virus infection and cardiovascular complications typical of tertiary syphilis, who required medical and surgical treatment, which was successful. We highlight the clinical experience of our institution's professionals in the diagnosis and identification of cardiovascular complications of tertiary syphilis.


A sífilis é causada pelo Treponema pallidum e é reconhecida pela variedade de suas manifestações clínicas; ela afeta os sistemas nervoso, tegumentar e cardiovascular. As alterações cardiovasculares ocorrem em 70% dos casos de sífilis não tratada, 71% dos casos de aortite sifilítica desenvolvem aneurismas aórticos e a complicação mais frequente é a insuficiência aórtica. O tratamento é direcionado para a doença subjacente, com tratamento antibiótico para sífilis terciária e complicações tromboembólicas e, se necessário, reparo cirúrgico. Apresentamos um caso raro de um paciente diagnosticado com infecção pelo vírus da imunodeficiência humana e complicações cardiovasculares típicas da sífilis terciária, que precisou de tratamento médico e cirúrgico, que foi bem-sucedido. Apresentamos um caso raro de um paciente com diagnóstico de infecção pelo vírus da imunodeficiência humana e complicações cardiovasculares típicas da sífilis terciária, que necessitou de tratamento médico e cirúrgico, o qual foi bem-sucedido. Destacamos a experiência clínica dos profissionais de nossa instituição no diagnóstico e na identificação das complicações cardiovasculares da sífilis terciária.


Subject(s)
Humans , Male , Adult , Aortic Aneurysm/surgery , Aortic Aneurysm/diagnostic imaging , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Aneurysm/etiology , Aortic Valve Insufficiency/etiology , Penicillin G Benzathine/therapeutic use , Syphilis, Cardiovascular/complications , Syphilis, Cardiovascular/diagnosis , Syphilis, Cardiovascular/drug therapy
6.
BioSCIENCE ; 81(2): 6-9, 2023.
Article in Portuguese | LILACS | ID: biblio-1524123

ABSTRACT

Introdução: Com o envelhecimento populacional brasileiro, esperase que a incidência de doenças cardiovasculares, como a estenose e insuficiência da válvula aórtica, eleve-se. Desde 2002, o implante valvar aórtico transcateter demonstrou-se método de alta eficácia no seu tratamento. No entanto, o procedimento está sujeito ao regurgitamento paravalvar. Objetivo: Avaliar quantitativamente a prevalência dessa regurgitação em pacientes submetidos ao Implante valvar aórtico transcateter. Métodos: Estudo observacional, transversal, retrospectivo que analisou 38 casos de Implante valvar aórtico transcateter. Os dados foram coletados dos prontuários, que incluíram informações antropométricas, comorbidades e procedimentos prévios à operação, e analisou-se a presença de refluxo paravalvar no 1° mês e 1° ano pós-Implante valvar aórtico transcateter. Resultados: A idade média foi de 74 ±11,2 anos; 15 pacientes dos analisados, possuíam classificação NYHA igual a III, e 1 NYHA IV, previamente à operação. Do total, 36,32% (n=8) tinham refluxo paravalvar no 1° mês e 1º. ano após o procedimento cirúrgico. Conclusão: A prevalência de refluxo paravalvar pós-operatório em pacientes submetidos ao Implante valvar aórtico transcateter, foi igual a 36,3% tanto para a avaliação realizada no 1° mês quanto no 1° ano.


Introduction: With the aging of the Brazilian population, it is expected that the incidence of cardiovascular diseases, such as stenosis and insufficiency of the aortic valve, will increase. Since 2002, transcatheter aortic valve implantation has proved to be a highly effective method of treatment. However, the procedure is subject to paravalvular regurgitation. Objective: To quantitatively assess the prevalence of paravalvular regurgitation in patients undergoing Transcatheter aortic valve implantation. Methods: Observational, cross-sectional, retrospective study that analyzed 38 Transcatheter aortic valve implantation cases. Data were collected from medical records, which included anthropometric information, comorbidities and procedures prior to the operation, and the presence of paravalvular regurgitation in the 1st month and 1st year after Transcatheter aortic valve implantation was analyzed. Results: Mean age was 74 ±11.2 years; 15 of the analyzed patients had NYHA classification equal to III, and 1 NYHA IV, prior to the operation. Of the total, 36.32% (n=8) of the patients had paravalvular regurgitation in the 1st and 1st month. year after the surgical procedure. Conclusion: The prevalence of postoperative paravalvular regurgitation in patients undergoing Transcatheter aortic valve implantation was equal to 36.3% both for the assessment carried out in the 1st month and in the 1st year


Subject(s)
Humans , Aortic Valve Stenosis , Cross-Sectional Studies
7.
Rev. bras. cir. cardiovasc ; 38(6): e20220370, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1507836

ABSTRACT

ABSTRACT Introduction: Aortic stenosis (AS) is the most common valvular heart disease and the most common indication for aortic valve replacement in adults. Aortic valve neocuspidization (AVNeo) with fixed autologous pericardium, also known as the Ozaki procedure, is a possible alternative treatment of AS. Autopericardial valves save the dynamics and physiological anatomy of the aortic root, however, the service life of autopericardial leaflets is limited. There is no data about factors that may influence the development of AVNeo insufficiency. Here, we assessed the effect of autopericardial leaflet symmetry on the development of aortic insufficiency after Ozaki procedure. Methods: This study included 381 patients with AS who underwent Ozaki procedure. Patients were divided into group 1 (171 patients with symmetric aortic root) and group 2 (210 patients with asymmetric aortic root). Results: The maximum observation period was up to 65 months. Sixteen cases of aortic insufficiency were detected in group 1, and 33 cases were detected in group 2. Based on the results of Cox regression, the predictors of aortic insufficiency in the late postoperative period are age and asymmetry of neocusps. According to results of Kaplan-Meier analysis, insufficiency of AVNeo in the maximum follow-up period after surgical correction of AS for group 1 patients was significantly lower than for group 2 patients (P=0.006). Conclusion: Asymmetric neocusps increase the risk of aortic insufficiency in the mid-term period after Ozaki procedure. And the older the patients at the time of surgery, the less likely they develop AVNeo insufficiency.

8.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 240-248, 2023.
Article in Chinese | WPRIM | ID: wpr-973495

ABSTRACT

@#Objective    To investigate effectiveness and safety of transcatheter aortic valve replacement in the treatment of aortic regurgitation. Methods     PubMed, EMbase, The Cochrane Library, Web of Science, CNKI, Wanfang Data and VIP were searched from inception to August 2021. According to the criteria of inclusion and exclusion, two reviewers independently screened the literature, extracted the data and evaluated the quality of the included studies. Then, Stata 16.0 software was used for meta-analysis. Subgroup meta-analysis of valve type used and study type was performed. Results    Twenty-five studies (12 cohort studies and 13 single-arm studies) were included with 4 370 patients. Meta-analysis results showed that an incidence of device success was 87% (95%CI 0.81-0.92). The success rate of the new generation valve subgroup was 93% (95%CI 0.89-0.96), and the early generation valve subgroup was 66% (95%CI 0.56-0.75). In addition, the 30-day all-cause mortality was 7% (95%CI 0.05-0.10), the 30-day cardiac mortality was 4% (95%CI 0.01-0.07), the incidence of pacemaker implantation was 10% (95%CI 0.08-0.13), and the incidence of conversion to thoraco-tomy was 2% (95%CI 0.01-0.04). The incidence of moderate or higher paravalvular aortic regurgitation was 6% (95%CI  0.03-0.09). Conclusion     Transcatheter aortic valve replacement for aortic regurgitation is safe and yields good results, but some limitations can not be overcome. Therefore, multicenter randomized controlled trials are needed to confirm our results.

9.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 1121-1127, 2023.
Article in Chinese | WPRIM | ID: wpr-996866

ABSTRACT

@#Objective     To investigate the left ventricular reverse remodeling (LVRR) in patients with aortic valve insufficiency with reduced ejection fraction (AIrEF) and aortic valve insufficiency with preserved ejection fraction (AIpEF) after transcatheter aortic valve replacement (TAVR). Methods    The clinical and follow-up data of patients who underwent TAVR in the Department of Cardiothoracic Surgery, Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine from 2018 to 2021 were retrospectively analyzed. According to the guideline, the patients with left ventricular ejection fraction<55% were allocated to an AIrEF group, and the patients with left ventricular ejection fraction≥55% were allocated to an AIpEF group. Results    A total of 50 patients were enrolled. There were 19 patients in the AIrEF group, including 15 males and 4 females with a mean age of 74.5±7.1 years. There were 31 patients in the AIpEF group, including 19 males and 12 females with a mean age of 72.0±4.8 years. All patients underwent TAVR successfully. Echocardiographic results showed that TAVR significantly promoted LVRR in the patients. Significant LVRR occurred in the early postoperative period (the first day after the surgery) in both groups. It remained relatively stable after the LVRR in the early postoperative period (the first day after surgery) in the AIpEF patients, while it continued to occur in the early postoperative period (the first day after surgery) to three months after the surgery in the AIrEF patients, and then remained relatively stable. Compared to preoperative values, AIrEF patients had a reduction in the average left ventricular end-diastolic volume index and left ventricular end-systolic volume index by 16.8 mL/m2 (P=0.003) and 8.6 mL/m2 (P=0.005), respectively, and the average left ventricular end-diastolic diameter index and end-systolic diameter index decreased by 2.5 mm/m2 (P=0.003) and 1.9 mm/m2 (P=0.003), respectively on the first day after the surgery. In comparison to the first day after the surgery, AIrEF patients experienced an average increase of 12.1% in the left ventricular ejection fraction three months after the surgery (P<0.001). Conclusion    TAVR has achieved good therapeutic effects in patients with aortic valve insufficiency, significantly promoting the LVRR in patients, and has better curative effects in AIrEF patients.

10.
Arch. cardiol. Méx ; 92(4): 438-445, Oct.-Dec. 2022. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1429677

ABSTRACT

Abstract Objective: In recent years, transcatheter aortic valve replace (TAVR) has revolutionized the interventional treatment of aortic stenosis, however, only scarce evidence considers it as treatment for Aortic Regurgitation (AR). At present, the treatment of Pure AR of Native Valve with TAVR does not fall within the recommendations of international guidelines, as it poses multiple challenges with immediate and long-term variable and unpredictable results. The objective of this paper is to present the case of a patient with prohibitive operative risk that benefited of TAVR treatment for AR. Materials and methods: We present the case of a 79-year-old male patient who has severe Pure Native Aortic Valve Regurgitation, considered inoperable. Based on the heart team's decision, TAVR was planned with the use of an Edwards SAPIEN 3 valve. After TAVR, the patient developed complete heart block and a pacemaker was implanted. He improved to NYHA II functional class. At 15-month follow-up, he suffered intracranial hemorrhage and passed away. Results and Conclusions: Management of patients with severe symptomatic AR with high surgical risk continues to be a special challenge. They have high mortality if left untreated with valvular change, despite medical treatment. Even though it is strictly off-label, TAVR might be a reasonable solution for a select type of patients who are considered inoperable due to surgical high mortality risk.


Resumen Objetivo: En años recientes, el reemplazo valvular aórtico vía percutánea (TAVI) ha revolucionado el tratamiento de los pacientes con estenosis aórtica, sin embargo, poca evidencia la considera como opción de tratamiento en pacientes con insuficiencia aórtica (IA), especialmente en pacientes con Insuficiencia Aórtica Pura de Válvula Nativa (IAPVN), dado que esta patología confiere múltiples retos con resultados muy variables tanto a corto como a largo plazo. Dada su alta mortalidad en caso de permanecer sin tratamiento, la primera opción de tratamiento es la cirugía de cambio valvular. Material y Métodos: Presentamos el caso de un masculino de 79 años con IAPVN grave considerado inoperable dadas las comorbilidades. De acuerdo con la decisión del equipo de Cardiología, se decidió realizar TAVI con la colocación de una Válvula Edwards SAPIEN 3. El paciente desarrolló bloqueo AV completo como única complicación y se colocó marcapasos permanente. Permaneció en clase funcional NYHA II. A los 15 meses de seguimiento presentó hemorragia intracraneal y falleció. Resultados y Conclusiones: El manejo de los pacientes con IAPVN grave sintomática con riesgo quirúrgico alto sigue siendo un reto especial. Tienen alta mortalidad si no se realiza cambio valvular a pesar de tratamiento médico. A pesar de que no se recomienda en las guías actuales, la TAVI puede ser una opción razonable para un grupo muy selecto de pacientes que son considerados inoperables.

11.
Rev. bras. cir. cardiovasc ; 37(2): 185-193, Apr. 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1376509

ABSTRACT

Abstract Introduction: Type A acute aortic dissection (AAD) remains a challenging cardiac emergency despite the availability of various management strategies. This study compared the outcomes of supracoronary ascending aortic replacement (SCAAR) with aortic valve (AV) resuspension with those of modified Bentall's operation for type A AAD and the progression of aortic regurgitation (AR), long-term dilatation of aortic root and proximal arch, and long-term mortality in SCAAR patients. Methods: Sixty patients underwent surgery for type A AAD (January 2005 to December 2015). Forty-three patients underwent SCAAR with AV resuspension and 17 underwent modified Bentall's operation. All patients were followed up. Results: Upon follow-up of SCAAR patients (n=40), there was significant reduction in aortic root size (preoperative 39.3 mm [9.4] vs. postoperative 33.1 mm [9.1]; P<0.001). Three of these patients worsened to severe AR while others had similar or lesser degree of AR. On comparison between preoperative and postoperative dimensions of all patients (n=53), there was no significant difference in distal ascending aorta size (35.7 mm [8.1] vs. 34.4 mm [8.9]; P=0.52). However, an increase in descending thoracic aorta size (28.8 mm [7.8] vs. 33.7 mm [9.9]; P<0.001) was observed. In-hospital and late mortalities for SCAAR vs. modified Bentall's procedure were 11.7% (seven patients) (7% [3] vs. 23.5% [4]) and 28% (15 patients) (15% [6] vs. 69% [9]), respectively. Conclusion: SCAAR with AV resuspension is a safe surgical option for type A AAD. Preservation of AV is associated with better long-term outcomes and reduced mortality. Modified Bentall's operation may be associated with long-term mortality.

12.
Rev. argent. cardiol ; 90(2): 112-119, abr. 2022. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1407125

ABSTRACT

RESUMEN Objetivo: Analizar si el implante más alto en el implante percutáneo de válvula aórtica (TAVI) con válvulas auto-expandibles utilizando la superposición de las cúspides derecha e izquierda disminuye la necesidad de marcapasos definitivo. Material y Métodos: Se analizaron 164 pacientes consecutivos que recibieron TAVI con válvulas auto- expandibles; en 101(61,6%) de ellos se implantaron utilizando la vista coplanar de las tres cúspides, a la cual llamamos técnica convencional (CON) y en 63 (38,4%) utilizamos la técnica COVL, con superposición de las cúspides derecha e izquierda . El punto final primario (PFP) fue la necesidad de marcapasos definitivo (MCPD) a 30 días. Resultado: No hubo diferencias entre los grupos en la edad media, prevalencia de sexo masculino, hipertensión, cirugía de revascularización previa, antecedente de accidente cerebrovascular (ACV), función renal, o hemodiálisis. Los pacientes en el grupo COVL tuvieron más diabetes, angioplastia coronaria (ATC) e infarto previos. La ATC pre-TAVI fue similar, con mayor score STS (6,3 ± 2,1 vs. 5,8 ± 2,4; p = 0,05). La presencia de fibrilación auricular fue mayor en el grupo COVL sin diferencia en bloqueo auriculoventricular, de rama derecha o izquierda. No hubo diferencia en el área valvular aórtica, gradiente medio y fracción de eyección ventricular izquierda. A 30 días se observó una reducción significativa del PFP en la estrategia COVL, (6,3% vs 17,8%, p = 0,03). No hubo diferencia en mortalidad, ACV, sangrado mayor, infarto agudo de miocardio o regurgitación aórtica. Hubo tendencia a menor presencia de nuevo bloqueo competo de rama izquierda en el grupo COVL (4,8% vs. 12,9%, p = 0,08). Conclusiones: El uso de la técnica de COVL, que permite un implante más alto en el TAVI con válvulas autoexpandibles, demostró en esta serie ser factible y seguro, con disminución de la necesidad de MCPD sin aumento de las complicaciones.


ABSTRACT Objective: The aim of this study was to analyze whether higher transcatheter aortic valve implantation with self-expandable valves using the right and left cusp overlap strategy decreases the need for permanent pacemaker. Methods: A total of 164 consecutive patients undergoing TAVI with self-expandable valves were analyzed: 101 (61.6%) implanted with the conventional technique (CON) using the three-cusp coplanar view, and 63 (38.4%) using the right and left cusp overlap (COVL) technique. The primary endpoint (PEP) was the need for permanent pacemaker (PPM) at 30 days. Results: Mean age, prevalence of male gender, hypertension, prior coronary artery bypass graft surgery (CABG), and history of stroke, kidney function or hemodialysis was not different between groups. Patients in the COVL group had more diabetes, coronary percutaneous transluminal coronary angioplasty (PTCA) and prior infarct, and pre-TAVI PTCA was similar, with higher STS score (6.3±2.2 vs. 5.8±2.4; p=0.05). The presence of atrial fibrillation was greater in the COVL group, without differences in right or left bundle branch or atrioventricular block. There was no difference in aortic valve area, mean gradient and left ventricular ejection fraction. At 30 days, the need of PPM was significantly reduced with the COVL technique (6.3%% vs. 17.8%; p=0.03). No difference was observed in mortality, stroke, major bleeding, acute myocardial infarction or aortic regurgitation, and the presence of new-onset complete left bundle branch block was lower in the COVL group (4.8% vs. 12.9%; p=0.08). Conclusions: Use of the COVL technique, which allows higher self-expandable valve implantation during TAVI, was feasible and safe, decreasing the need for PPM without increasing complications.

13.
Journal of Chinese Physician ; (12): 1047-1050, 2022.
Article in Chinese | WPRIM | ID: wpr-956262

ABSTRACT

Objective:This study sought to investigate the feasibility, anatomical indications and operating points of transcatheter aortic valve replacement (TAVR) procedure in the treatment of pure aortic regurgitation (AR).Methods:The medical records of 4 elderly patients with pure AR who were treated in the cardiology department, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology from March 2020 to March 2021 were retrospectively analyzed. All patients were implanted with self-expandable valve stents via peripheral artery approach for TAVR treatment. The feasibility, anatomical indications and key points of TAVR were analyzed.Results:The 4 patients with pure AR who were carefully screened had an average age of 66 years, and all achieved TAVR treatment success without serious perioperative complications and death. Postoperative examination and follow-up data showed that cardiac functions and cardiac remodeling indexes were significantly improved.Conclusions:This exploratory study shows that TAVR is technically feasible and effective treatment option for selected elderly patients with native pure AR, which is worthy of further study.

14.
ABC., imagem cardiovasc ; 35(2): eabc304, 2022. ilus, tab
Article in Portuguese | LILACS | ID: biblio-1400334

ABSTRACT

Introdução: A função sistodiastólica do ventrículo esquerdo é prognóstica nas doenças cardiovasculares e pode ser avaliada por strain longitudinal global por meio de ecocardiografia e de ressonância magnética cardíaca. O strain longitudinal global pela ressonância magnética cardíaca exige a utilização de software de alto custo. O deslocamento linear longitudinal do ventrículo esquerdo pode ser uma alternativa simples e barata ao strain longitudinal global, porém eles não foram ainda comparados sistematicamente. Objetivo: Comparar o deslocamento linear longitudinal com o strain longitudinal global e fração de ejeção do ventrículo esquerdo em valvopatas aórticos e controles. Métodos: Incluímos 44 participantes (26 valvopatas aórticos/19 controles). O strain longitudinal global utilizou software específico (Circle Cardiovascular Imaging 42) e o deslocamento linear longitudinal apenas medidas lineares de distância entre a base e o ápex do ventrículo esquerdo, gerando deslocamento máximo, velocidade máxima no início da diástole, velocidade na diástase e a relação entre velocidade na diástase e velocidade máxima no início da diástole. Resultados: Deslocamento máximo e velocidade máxima no início da diástole correlacionaram-se com strain longitudinal global (r=0,69 e r=0,65 respectivamente) e com a fração de ejeção do ventrículo esquerdo (r=0,47 e r=0,57, p<0,001 para ambos). Deslocamento máximo e velocidade máxima no início da diástole apresentaram área sob a curva Característica de Operação do Receptor de 0,88 e 0,91 e, no melhor ponto de corte (-0,13 e 0,66), sensibilidade de 72,43% e 57,14% e especificidade 80,65% e 87,10%, respectivamente, quando comparados ao strain longitudinal global. Utilizando a fração de ejeção do ventrículo esquerdo como referência, foram obtidos 0,70 e 0,82, e, no melhor ponto de corte (-0,11 e 0,61), sensibilidade de 75,00% e 50,00% e especificidade 72,97% e 78,38%, respectivamente. Conclusão: O deslocamento linear longitudinal foi semelhante ao strain longitudinal global. O deslocamento máximo derivado do deslocamento linear longitudinal foi o melhor parâmetro na sístole, enquanto a velocidade máxima no início da diástole foi o melhor na diástole, o que possibilita a avaliação da função diastólica pela ressonância magnética cardíaca na rotina clínica de forma rápida e sem custo adicional.(AU)


Background: Left ventricular (LV) systolic diastolic function is prognostic in cardiovascular diseases and can be assessed via global longitudinal strain (GLS) on echocardiography and cardiac magnetic resonance (CMR). However, GLS by CMR requires the use of expensive software. Longitudinal linear displacement (LLD) may be a simple and inexpensive alternative to GLS, but the two have not been systematically compared. Objective: To compare LLD with GLS and LV ejection fraction (LVEF) in aortic valve disease patients and controls. Methods: We included 44 participants (26 with aortic valve disease, 19 controls). GLS was determined using CVI42 software (Circle Cardiovascular Imaging), while the LLD linear measurements of the distance between the base/apex of the LV included maximum displacement (MD), maximum velocity in early diastole (MVED), atrioventricular junction velocity in diastasis (VDS), and VDS/MVED ratio. Results: DM and MVED were correlated with GLS (r=0.69 and r=0.65, respectively) and LVEF (r=0.47 and r=0.57, p<0.001 for both). DM and MVED showed areas under the receiver operating characteristic curve (AUC) of 0.88 and 0.91, and at the best cut-off point (-0.13 and 0.66), sensitivities of 72.43% and 57.14% and specificities of 80.65% and 87.10%, respectively, compared to GLS. Using LVEF as a reference, we obtained AUC of 0.70 and 0.82, and at the best cut-off point (-0.11 and 0.61), sensitivities of 75.00% and 50.00% and specificities of 72.97% and 78.38%, respectively. Conclusion: LLD demonstrated similar performance to that of GLS. MD derived from LLD was the best parameter during systole, while MVED was the best during diastole. Our findings demonstrate the routine, quick, and inexpensive assessment of diastolic function on CMR.(AU)


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Stroke Volume/physiology , Echocardiography/methods , Ventricular Function, Left , Aortic Valve Disease/diagnosis , Myocardial Contraction/physiology , Aortic Valve Insufficiency/diagnostic imaging , Blood Flow Velocity , Magnetic Resonance Spectroscopy/methods , Heart Ventricles/pathology
15.
Rev. bras. cir. cardiovasc ; 36(6): 807-816, Nov.-Dec. 2021. tab, graf
Article in English | LILACS | ID: biblio-1351668

ABSTRACT

Abstract Introduction: The presence of aortic regurgitation (AR) in the setting of ventricular septal defect (VSD) has always been a management challenge. Methods: This is a retrospective study looking at patients who underwent VSD closure with or without aortic valve intervention between January 1st, 1992 and December 31st, 2014 at the Institute Jantung Negara. This study looked at all cases of VSD and AR, where AR was classified as mild, moderate, and severe, the intervention done in each of this grade, and the durability of that intervention. The interventions were classified as no intervention (NI), aortic valve repair (AVr), and aortic valve replacement (AVR). Results: A total of 261 patients were recruited into this study. Based on the various grades of AR, 105 patients had intervention to their aortic valve during VSD closure. The rest 156 had NI. All patients were followed up for a mean time of 13.9±3.5 years. Overall freedom from reoperation at 15 years was 82.6% for AVr. Various factors were investigated to decide on intervening on the aortic valve during VSD closure. Among those that were statistically significant were the grade of AR, size of VSD, age at intervention, and number of cusp prolapse. Conclusion: We can conclude from our study that all moderate and severe AR with small VSD in older patients with more than one cusp prolapse will need intervention to their aortic valve during the closure of VSD.


Subject(s)
Humans , Aged , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/complications , Aortic Valve Prolapse/surgery , Aortic Valve Prolapse/complications , Aortic Valve Prolapse/diagnostic imaging , Heart Septal Defects, Ventricular/surgery , Heart Septal Defects, Ventricular/complications , Prolapse , Syndrome , Retrospective Studies , Treatment Outcome
16.
Rev. bras. cir. cardiovasc ; 36(2): 192-200, Mar.-Apr. 2021. tab, graf
Article in English | LILACS | ID: biblio-1251087

ABSTRACT

Abstract Introduction: Valve-reimplantation and remodelling techniques used in aortic reconstruction provide successful early, mid, and long-term results. We present our early and late-term experience with 110 patients with aortic regurgitation (AR) who underwent aortic valve repair (AVr) or valve-sparing aortic root surgeries (VSARS) due to aortic dissection or aortic aneurysm. Methods: Nine hundred eighty-two patients who underwent aneurysm or dissection surgery and aortic valve surgery between April 1997 and January 2017 were analysed using the patient database. A total of 110 patients with AR who underwent AVr or VSARS due to aortic dissection or aortic aneurysm were included in the study. Results: In the postoperative period, a decrease was observed in AR compared to the preoperative period (P<0.001); there was an increase in postoperative ejection fraction (EF) compared to the preoperative values (P<0.005) and a significant decrease in postoperative left ventricle diameters compared to the preoperative values (P<0.001). Kaplan-Meier analysis revealed one, two, four, and five-year freedom from moderate-severe AR as 95%, 91%, 87%, and 70%, respectively. Freedom from reoperation in one, two, and five years were 97.9%, 93.6%, and 81%, respectively. Eight patients (7.4%) underwent AVr during follow-up. Out of the remaining 100 patients, 13 (12%) had minimum AR, 52 (48%) had 1st-2nd degree AR, and 35 (32%) had 2nd-3rd degree AR during follow-up. Conclusion: For the purpose of maintaining the native valve tissue, preserving the EF and the left ventricular end-diastolic diameter, valve-sparing surgeries should be preferred for appropriate patients.


Subject(s)
Aortic Aneurysm/surgery , Aortic Aneurysm/complications , Aortic Valve Insufficiency/surgery , Aortic Dissection/surgery , Aortic Valve/surgery , Reoperation , Retrospective Studies , Follow-Up Studies , Treatment Outcome
17.
Rev. bras. cir. cardiovasc ; 36(1): 48-56, Jan.-Feb. 2021. tab, graf
Article in English | LILACS | ID: biblio-1155787

ABSTRACT

Abstract Objective: To evaluate the efficacy of hybrid transthoracic periventricular device closure of ventricular septal defects (VSDs) in a single center. Methods: All patients who underwent hybrid transthoracic periventricular device closure of VSDs between January 2018 and December 2019 were retrospectively analyzed. The preoperative, operative and postoperative findings and clinical follow-ups were reviewed. Results: A total of 59 patients underwent the procedure. Transesophageal echocardiographic guidance was used in all procedures. The procedure was successful in 57 procedures (97%). The procedures of two patients were changed to open-heart surgery during the same intervention due to severe aortic insufficiency (the device was not deployed) and significant residual shunt after device deployment. One major complication (1.7%) was observed after the procedure. The patient's device was dislodged within 12 hours after the procedure, and this patient underwent device extraction and VSD patch closure due to significant residual shunt. Eight (14%) minor complications were observed after the procedure, and three of them persisted during follow-up. Three of these eight complications were incomplete right bundle branch block, one of which resolved during follow-up; two were mild residual shunts, one of which resolved during follow-up; two were mild new-onset tricuspid valve insufficiencies; and one was mild new-onset mitral valve insufficiency; all valvular insufficiencies were resolved during follow-up. Conclusions: Hybrid transthoracic periventricular device closure of VSD seems to be a good alternative approach due to its procedural success and low risk rates. The best advantage of the procedure is the possibility of switching to open-heart surgery, if necessary.


Subject(s)
Humans , Male , Female , Infant , Septal Occluder Device , Heart Septal Defects, Ventricular/surgery , Heart Septal Defects, Ventricular/diagnostic imaging , Cardiac Catheterization , Retrospective Studies , Follow-Up Studies , Treatment Outcome , Echocardiography, Transesophageal
18.
Rev. bras. cir. cardiovasc ; 36(1): 130-132, Jan.-Feb. 2021. tab, graf
Article in English | LILACS | ID: biblio-1155797

ABSTRACT

Abstract Aortic valve endocarditis can lead to secondary involvement of aorto-mitral curtain and the adjacent anterior mitral leaflet (AML). The secondary damage to AML is often caused by the infected jet of aortic regurgitation hitting the ventricular surface of the mitral leaflet, or by the pronounced bacterial vegetation that prolapses from the aortic valve into the left ventricular outflow tract. This is called 'kissing lesion'. We describe a patient with infective endocarditis of the aortic valve causing perforation of both noncoronary cusp of aortic valve and the AML, which is rare.


Subject(s)
Humans , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/diagnostic imaging , Endocarditis, Bacterial/surgery , Endocarditis, Bacterial/complications , Endocarditis, Bacterial/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve Insufficiency
19.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 757-764, 2021.
Article in Chinese | WPRIM | ID: wpr-886496

ABSTRACT

@#Objective    To investigate the feasibility and safety of transcatheter aortic valve replacement (TAVR) through apical approach for aortic regurgitation of large annulus. Methods    From November 2019 to May 2020, 10 male patients aged 64.50±4.20 years with aortic valve insufficiency (AI) underwent TAVR in the Department of Cardiovascular Surgery, Xijing Hospital. The surgical instruments were 29# J-valveTM modified and the patients underwent TAVR under angiography. The preoperative and postoperative cardiac function, valve regurgitation, complications and left ventricular remodeling were summarized by ultrasound and CT before and after TAVR. Results    A total of 10 valves were implanted in 10 patients. Among them, 1 patient was transferred to the aortic arch during the operation and was transferred to surgical aortic valve replacement; the other 9 patients were successfully implanted with J-valve, with 6 patients of cardiac function (NYHA) class Ⅱ, 4 patients of grade Ⅲ. And there was a significant difference between preoperation and postoperation in left ventricular ejection fraction (44.70%±8.78% vs. 39.80%±8.48%, P<0.05) or aortic regurgitation (1.75±0.72 mL vs. 16.51±8.71 mL, P<0.05). After 3 months, the patients' cardiac function was good. Conclusion    TAVR is safe and effective in the treatment of severe valvular disease with AI using J-valve.

20.
Arq. bras. cardiol ; 115(2): 253-260, ago., 2020. tab, graf
Article in English, Portuguese | LILACS, SES-SP | ID: biblio-1131283

ABSTRACT

Resumo Fundamento A ecocardiografia é essencial para o diagnóstico e a quantificação da insuficiência aórtica (IA). A integral velocidade-tempo (IVT) do fluxo da IA pode estar relacionada à gravidade da IA. Objetivo Este estudo tem por objetivo avaliar se a IVT é um marcador ecocardiográfico de gravidade da IA. Métodos Foram incluídos todos os pacientes com IA nativa moderada ou grave e ritmo sinusal que visitaram o nosso laboratório de imagem entre janeiro e outubro de 2016. Todos os indivíduos foram submetidos a um ecocardiograma completo com medição da IVT da IA. A associação entre a IVT e a gravidade da IA foi analisada por regressão logística e modelos de regressão multivariada. Valores p<0,05 foram considerados estatisticamente significativos. Resultados Entre os 62 pacientes incluídos (68,5±14,9 anos; 64,5%: IA moderada; 35,5%: IA grave), a IVT foi maior em indivíduos com IA moderada em comparação àqueles com IA grave (2,2±0,5 m versus 1,9±0,5 m, p=0,01). Pacientes com IA grave apresentaram valores maiores de diâmetro diastólico final do ventrículo esquerdo (DDFVE) (56,1±7,1 mm versus 47,3±9,6 mm, p=0,001), volume diastólico final do ventrículo esquerdo (VDFVE) (171±36,5 mL versus 106±46,6 mL, p<0,001), orifício regurgitante efetivo (0,44±0,1 cm2 versus 0,18±0,1 cm2, p=0,002) e volume regurgitante (71,3±25,7 mL versus 42,5±10,9 mL, p=0,05), assim como menor fração de ejeção do ventrículo esquerdo (FEVE) (54,1±11,2% versus 63,2±13,3%, p=0,012). A IVT mostrou ser um marcador de gravidade da IA, independentemente do DDFVE, VDFVE e FEVE ( odds ratio 0,160, p=0,032) e da frequência cardíaca e pressão arterial diastólica (PAD) ( odds ratio 0,232, p=0,044). Conclusões A IVT do fluxo da IA apresentou associação inversa com a gravidade da IA, independentemente do diâmetro e volume do ventrículo esquerdo, frequência cardíaca, PAD e FEVE. A IVT pode ser um marcador de gravidade da IA em pacientes com IA nativa e ritmo sinusal. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Abstract Background Echocardiography is essential for the diagnosis and quantification of aortic regurgitation (AR). Velocity-time integral (VTI) of AR flow could be related to AR severity. Objective This study aims to assess whether VTI is an echocardiographic marker of AR severity. Methods We included all patients with moderate or severe native AR and sinus rhythm who visited our imaging laboratory from January to October 2016. All individuals underwent a complete echocardiogram with AR VTI measurement. The association between VTI and AR severity was analyzed by logistic regression and multivariate regression models. A p-value<0,05 was considered statistically significant. Results Among the 62 patients included (68.5±14.9 years old; 64.5%: moderate AR; 35.5%: severe AR), VTI was higher in individuals with moderate AR compared to those with severe AR (2.2±0.5 m vs. 1.9±0.5 m, p=0.01). Patients with severe AR presented greater values of left ventricular end-diastolic diameter (LVEDD) (56.1±7.1 mm vs. 47.3±9.6 mm, p=0.001), left ventricular end-diastolic volume (LVEDV) (171±36.5 mL vs. 106±46.6 mL, p<0.001), effective regurgitant orifice (0.44±0.1 cm2vs. 0.18±0.1 cm2, p=0.002), and regurgitant volume (71.3±25.7 mL vs. 42.5±10.9 mL, p=0.05), as well as lower left ventricular ejection fraction (LVEF) (54.1±11.2% vs. 63.2±13.3%, p=0.012). The VTI proved to be a marker of AR severity, irrespective of LVEDD, LVEDV, and LVEF (odds ratio 0.160, p=0.032) and of heart rate and diastolic blood pressure (DBP) (odds ratio 0.232, p=0.044). Conclusions The VTI of AR flow was inversely associated with AR severity regardless of left ventricular diameter and volume, heart rate, DBP, and LVEF. VTI could be a marker of AR severity in patients with native AR and sinus rhythm. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Subject(s)
Humans , Aged , Aged, 80 and over , Aortic Valve Insufficiency/diagnostic imaging , Stroke Volume , Time , Severity of Illness Index , Echocardiography , Ventricular Function, Left , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL